SIGMAKOKI

Register


PFL-UV-AG
Item name
Design wavelength
Magnification
Numerical aperture (NA)
Working distance (WD)
Focal length f
Resolution (λ=550nm)
Focal depth (λ=550nm)
Pupil diameter
Real field of View (Eyepiece φ24mm)
Real field of View (Imaging device 1/2-inch)
Zoom

This objective lens can be used for laser machining using pulsed laser of SHG (532nm) YAG laser and FHG (266nm) YAG. Chromatic aberration is suppressed in both the visible and UV laser wavelength, achieving a high transmittance.

◦With its long working distance and field curvature corrected, its natural observation image is obtained to the periphery of the visual field.
◦It is the long working infinity correction function that is used to introduce a laser system and coaxial observation.
◦It is also used for the observation of ultra-violet light.
◦Laser Damage Threshold (Typical) 0.09 J/cm2 (266nm), 0.2J/cm2 (532nm) (Laser pulse width 10ns, repetition frequency 20Hz)

Related product
Products
Technical Data
Documents/Downloads
Guide

▶Available fixed objective lens holder (LHO-26).
W4024
▶When the objective lens is fixed to a 2 axis holder, please consult our Sales Division.
▶▶For laser processing, we offer a dichroic block (DIMC W2041) and for laser unit with coaxial illumination and observation (OUCI-2).

Attention

▶When an objective lens is used in laser processing, use the diameter of the incident beam to extend to a size of half the pupil diameter (1/e2). A small light spot cannot be achieved when the incident beam is too narrow. Please note if there is a laser energy density increase, there will be a high possibility of damage to the objective lens.
▶The surface of an objective lens can be contaminated by debris during processing. To avoid this, please have sufficient working distance (WD) and insert a thin protective glass on the objective.
▶Magnification is the value when using the imaging lens f=200mm. When used in a microscope lens barrel from other manufacturers there may be different magnifications. The actual magnification should be calculated from the ratio of the focal length of the objective lens and the focal length of the imaging lens to verify the focal length of the imaging lens barrel to be used.

Outline Drawing
■PFL-10-UV-AG-A

Zoom
■PFL-20-UV-AG-A

Zoom
■PFL-50-UV-AG-A

Zoom
■PFL-80-UV-AG-LC00

Zoom
Typical Transmittance Data

Zoom
T: Transmission
Spec
Compare
Part Number
Add to cart Cart
    JP Yen Stock Qty
PFL-10-UV-AG機種変更
PFL-10-UV-AG-A
PFL-20-UV-AG-A
PFL-50-UV-AG-A
PFL-80-UV-AG-LC00
PFL-20-UV-AG取扱い中止
PFL-50-UV-AG取扱い中止
PFL-10-NUV-AG取扱い中止
PFL-20-NUV-AG取扱い中止
PFL-50-NUV-AG取扱い中止

Mplan UV 10x

266nm

10×

0.2

13.5mm

20mm

1.4μm

±6.9μm

φ8mm

φ2.4mm

0.48×0.64mm

0.3kg

Mplan UV 10x

266nm

10×

0.2

13.5mm

20mm

1.4μm

±6.9μm

φ8mm

φ2.4mm

0.48×0.64mm

0.3kg

Mplan UV 20x

266nm

20×

0.36

15.1mm

10mm

0.76μm

±2.1μm

φ7.2mm

φ1.2mm

0.24×0.32mm

0.35kg

Mplan UV 50x

266nm

50×

0.42

12mm

4mm

0.65μm

±1.6μm

φ3.4mm

φ0.48mm

0.10×0.13mm

0.41kg

Mplan UV 80x

266nm

80×

0.55

10mm

2.5mm

0.5μm

±0.9μm

φ2.8mm

φ0.3mm

0.06×0.08mm

0.35kg

-

266nm

20×

0.36

10mm

10mm

0.8μm

±2.1μm

φ7.2mm

φ1.2mm

0.24×0.32mm

0.32kg

-

266nm

50×

0.42

10mm

4mm

0.7μm

±1.6μm

φ3.4mm

φ0.48mm

0.10×0.13mm

0.32kg

Mplan NUV 10x

355nm

10×

0.2

13.5mm

20mm

1.4μm

±6.9μm

φ8mm

φ2.4mm

0.48×0.64mm

0.3kg

Mplan NUV 20x

355nm

20×

0.36

10mm

10mm

0.8μm

±2.1μm

φ7.2mm

φ1.2mm

0.24×0.32mm

0.32kg

Mplan NUV 50x

355nm

50×

0.42

10mm

4mm

0.7μm

±1.6μm

φ3.4mm

φ0.48mm

0.10×0.13mm

0.32kg

    - - -
RoHS  

¥950,000

CONTACT
US
RoHS  

¥880,000

CONTACT
US
RoHS  

¥960,000

IN STOCK
RoHS  

CONTACT US

CONTACT
US
RoHS   - - -
    - - -
    - - -
    - - -
    - - -